CoreBuilder 6000/2500 - username: debug password: synnet
CoreBuilder 3500 (Version 1.0) - username: debug password: synnet
CoreBuilder 7000 - username: tech password: tech
SuperStack II Switch 2200 - username: debug password: synnet
SuperStack II Switch 2700 - username: tech password: tech
The CoreBuilder 3500 (Version 1.1), SuperStack II Switch 3900 and 9300 also have these mechanisms, but the special login password is changed to match the admin level password when the admin level password is changed.
Customers should also immediately change the SNMP Community string from the default to a proprietary and confidential identifier known only to authorized network management staff. This is due to the fact that the admin password is available through a specific proprietary MIB variable when accessed through the read/write SNMP community string.
This issue applies only to the CoreBuilder 2500/6000/3500 and SuperStack II Switch 2200/3900/9300.
Fixed versions of software for CoreBuilder 2500/6000/3500 and SuperStack II Switch 2200/3900/9300 are available below.
General administration of these systems should still be performed through the normal documented usernames and passwords. Other facilities found under these special logins are for diagnostic purposes and should only be used under specific guidance from 3Com''s Customer Service Organization.
[责任编辑:editorforddvip]
相关链接
本栏更新